Ring Blowers (Catalog [PDF])
| ring blower | high pressure ring blower (with motor) |
Mini ring blower (with external Controller) |
|
|---|---|---|---|
| with motor | with belt drive (no motor) |
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|

Side channel blower (also named: Regenerative blower, Ring blower, Vortex blower)
are used everywhere when it is necessary to move air or gas (with vacuum or pressure).
Side channel blowers are build in different sizes and technic depending on the air flow
or pressure / vacuum that is needed:
single stage ring blower for medium air volumes
double stage ring blower for higher pressures
double flute ring blower for higher air volumes
single stage high pressure ring blower for high pressures
double stage high pressure ring blower for higher pressures
three stage high pressure blower for very high pressures
Side channel blower - Function
while the resulting centrifugal force pushes the gas outwards into the side channel.
In this way, spiral-shaped turbulences are created. During these turbulences, the
Side Channel Blowers - Applications
Mechanical engineering
Within mechanical engineering and construction, side channel blowers are used everywhere,
where it is necessary to compress or to suction air and various gases. They are for example
frequently used in vacuum grippers to transport flat pieces.
Another frequent usage is to dry surfaces after galvanic baths or cleaning with water. Here the high speed
of air flow, typically increased by air knives, is used to forcibly remove the droplets.
Construction
Ring blowers are also used, for example remediating damage caused by water. The aim is to remove
humidity from a layer within the wall, usually the insulation layer. Dry air is pressed into the wet insulation layer or under different operating
principles, the air is being sucked out of it, the warm air slowly absorbs the humidity and removes it from the contaminated layer. A certain
pressure is needed to create an airflow within the dense insulation layer. For removing larger ammounts of water, side channel blowers are
used as well. Water can be sucked out of the insulation layer and is then removed in a separator. On the other hand, clean water can also be
pressed into the insulation layer to purge it of possible contaminents.
Other applications
Whirlpools
Pond ventilation
Biogas plants
Wood gas
Fish farms
Hoovers
Swimming pools
Vacuum tables
and much more
Single stage ring blower with following specifications for 50 Hz: Max. air flow: 318 m³/hConnection thread: G 2" table { border-collapse: collapse; width: 100%; } td, th { padding: 5px; } tr:nth-child(even) { background-color: #dddddd; } Model Curves Phases Motorpower[kW] Energyclassi-fication Voltage[V] Current[A] Pressuremax. [mbar] Vacuummax. [mbar] SKV-NS-318-3-906 A290 3~ 1,6 IE1 200-240 Δ / 345-415 Y 4,9 +150 -160 SKV-NS-318-3-916 A292 3~ 2,2 IE1 200-240 Δ / 345-415 Y 5,6 +190 -190 SKV-NS-318-3-926 A294 3~ 3,0 IE1 200-240 Δ / 345-415 Y 7,2 +270 -260 SKV-NS-318-3-937 A296 3~ 4,0 IE1 345-415 Δ / 600-720 Y 9,5 +360 -290 SKV-NS-318-3-806 1 3~ 1,5 IE2 Sold out -> Replacement model: SKV-NS-318-3-706 SKV-NS-318-3-816 2 3~ 2,2 IE2 200-260 Δ / 350-450 Y 4,6 +170 -180 SKV-NS-318-3-826 3 3~ 3,0 IE2 200-260 Δ / 350-450 Y 6,5 +250 -260 SKV-NS-318-3-836 4 3~ 4,0 IE2 Sold out -> Replacement model: SKV-NS-318-3-736 SKV-NS-318-3-706 1 3~ 1,75 IE3 200-240 Δ / 380-420 Y 3,45 +120 -130 SKV-NS-318-3-P16 2 3~ 2,5 IE3 190-210 YY /220-240 Δ / 380-420 Y 5,0 +190 -200 SKV-NS-318-3-726 3 3~ 3,45 IE3 200-240 Δ / 380-420 Y 6,9 +270 -260 SKV-NS-318-3-736 4 3~ 4,6 IE3 200-240 Δ / 380-420 Y 8,6 +360 -290 For 3-D drawings / STEP files please send us an e-mail.
Double stage ring blower with following specifications for 50 Hz: Max. air flow: 320 m³/hConnection thread: G 2" table { border-collapse: collapse; width: 100%; } td, th { padding: 5px; } tr:nth-child(even) { background-color: #dddddd; } Model Curves Phases Motorpower[kW] Energyclassi-fication Voltage[V] Current[A] Pressuremax. [mbar] Vacuummax. [mbar] SKV-ND-320-3-916 A300 3~ 2,2 IE1 200-240 Δ / 345-415 Y 5,6 +190 -200 SKV-ND-320-3-926 A302 3~ 3,0 IE1 200-240 Δ / 345-415 Y 7,2 +250 -250 SKV-ND-320-3-937 A304 3~ 4,3 IE1 345-415 Δ / 600-720 Y 10,0 +360 -360 SKV-ND-320-3-947 A306 3~ 5,5 IE1 345-415 Δ / 600-720 Y 13,3 +500 -420 SKV-ND-320-3-957 A308 3~ 7,5 IE1 345-415 Δ / 600-720 Y 16,7 +610 -420 SKV-ND-320-3-826 1 3~ 3,0 IE2 Sold out -> Replacement model: SKV-ND-320-3-P26 SKV-ND-320-3-836 2 3~ 4,0 IE2 Sold out -> Replacement model: SKV-ND-320-3-P36 SKV-ND-320-3-837 2 3~ 4,0 IE2 Sold out -> Replacement model: SKV-ND-320-3-737 SKV-ND-320-3-846 3 3~ 5,5 IE2 200-260 Δ / 350-450 Y 11,1 +460 -420 SKV-ND-320-3-856 4 3~ 7,5 IE2 200-260 Δ / 350-450 Y 15,0 +610 -420 SKV-ND-320-3-P16 1 3~ 2,5 IE3 190-210 YY /220-240 Δ / 380-420 Y 5,0 +160 -170 SKV-ND-320-3-P26 2 3~ 3,45 IE3 190-210 YY /220-240 Δ / 380-420 Y 6,7 +260 -270 SKV-ND-320-3-P36 3 3~ 4,6 IE3 190-210 YY /220-240 Δ / 380-420 Y 8,6 +360 -400 SKV-ND-320-3-737 3 3~ 4,6 IE3 380-420 Δ / 660-725 Y 8,6 +360 -400 SKV-ND-320-3-P46 4 3~ 6,3 IE3 190-210 YY /220-240 Δ / 380-420 Y 11,8 +530 -420 SKV-ND-320-3-P56 5 3~ 8,6 IE3 190-210 YY /220-240 Δ / 380-420 Y 15,5 +610 -420 For 3-D drawings / STEP files please send us an e-mail.
double stage ring blower with belt drive: SKV-ND-320-BD Connection thread: G 2"Motor: not included Speed (rpm): 3000 3600 4200 5000 Air flow (m³/h): 320 380 440 530 Pressure max: (mbar) 570 660 600 410 Vacuum max: (mbar) 440 460 460 440 For 3-D drawings / STEP files please send us an e-mail.
Single stage ring blower with following specifications for 50 Hz: Max. air flow: 420 m³/hConnection thread: G 2" table { border-collapse: collapse; width: 100%; } td, th { padding: 5px; } tr:nth-child(even) { background-color: #dddddd; } Model Curves Phases Motorpower[kW] Energyclassi-fication Voltage[V] Current[A] Pressuremax. [mbar] Vacuummax. [mbar] SKV-NS-420-3-906 A310 3~ 1,6 IE1 200-240 Δ / 345-415 Y 4,9 +100 -100 SKV-NS-420-3-916 A312 3~ 2,2 IE1 200-240 Δ / 345-415 Y 5,6 +170 -180 SKV-NS-420-3-926 A314 3~ 3,0 IE1 200-240 Δ / 345-415 Y 7,2 +200 -220 SKV-NS-420-3-937 A316 3~ 4,0 IE1 345-415 Δ / 600-720 Y 9,5 +290 -260 SKV-NS-420-3-806 1 3~ 1,5 IE2 Sold out -> Replacement model: SKV-NS-420-3-P16 SKV-NS-420-3-816 2 3~ 2,2 IE2 200-260 Δ / 350-450 Y 4,6 +120 -130 SKV-NS-420-3-826 3 3~ 3,0 IE2 200-260 Δ / 350-450 Y 6,5 +200 -210 SKV-NS-420-3-836 4 3~ 4,0 IE2 Sold out -> Replacement model: SKV-NS-420-3-736 SKV-NS-420-3-P16 1 3~ 2,5 IE3 190-210 YY /220-240 Δ / 380-420 Y 5,0 +150 -160 SKV-NS-420-3-P26 2 3~ 3,45 IE3 190-210 YY /220-240 Δ / 380-420 Y 6,9 +220 -240 SKV-NS-420-3-736 3 3~ 4,6 IE3 220-240 Δ / 380-420 Y 8,6 +320 -260 For 3-D drawings / STEP files please send us an e-mail.
Triple stage high pressure ring blower with following specifications for 50 Hz: Max. air flow: 480 m³/hConnection thread: G 3" table { border-collapse: collapse; width: 100%; } td, th { padding: 5px; } tr:nth-child(even) { background-color: #dddddd; } Model Curves Phases Motorpower[kW] Energyclassi-fication Voltage[V] Current[A] Pressuremax. [mbar] Vacuummax. [mbar] SKV-HT-480-3-P66 1 3~ 12,6 IE3 190-210 YY /220-240 Δ / 380-420 Y 23,3 +640 -610 SKV-HT-480-3-776 2 3~ 17,3 IE3 220-240 Δ / 380-420 Y 31,7 +980 -610 SKV-HT-480-3-P86 3 3~ 21,3 IE3 190-210 YY /220-240 Δ / 380-420 Y 38,3 +1020 -610 For 3-D drawings / STEP files please send us an e-mail.
Double stage high pressure ring blower with following specifications for 50 Hz: Max. air flow: 480 m³/hConnection thread: G 3" table { border-collapse: collapse; width: 100%; } td, th { padding: 5px; } tr:nth-child(even) { background-color: #dddddd; } Model Curves Phases Motorpower[kW] Energyclassi-fication Voltage[V] Current[A] Pressuremax. [mbar] Vacuummax. [mbar] SKV-HD-480-3-P56 1 3~ 8,6 IE3 190-210 YY /220-240 Δ / 380-420 Y 15,5 +450 -530 SKV-HD-480-3-766 2 3~ 12,6 IE3 220-240 Δ / 380-420 Y 23,3 +760 -530 SKV-HD-480-3-776 3 3~ 17,3 IE3 220-240 Δ / 380-420 Y 31,7 +890 -530 For 3-D drawings / STEP files please send us an e-mail.
Single stage high pressure ring blower with following specifications for 50 Hz: Max. air flow: 480 m³/hConnection thread: G 3" table { border-collapse: collapse; width: 100%; } td, th { padding: 5px; } tr:nth-child(even) { background-color: #dddddd; } Model Curves Phases Motorpower[kW] Energyclassi-fication Voltage[V] Current[A] Pressuremax. [mbar] Vacuummax. [mbar] SKV-HS-480-3-P36 1 3~ 4,6 IE3 190-210 YY /220-240 Δ / 380-420 Y 8,6 +240 -270 SKV-HS-480-3-746 2 3~ 6,3 IE3 220-240 Δ / 380-420 Y 11,8 +400 -380 SKV-HS-480-3-756 3 3~ 8,6 IE3 220-240 Δ / 380-420 Y 15,5 +550 -380 For 3-D drawings / STEP files please send us an e-mail.
Double flute ring blower with following specifications for 50 Hz: Max. air flow: 500 m³/hConnection thread: G 2" table { border-collapse: collapse; width: 100%; } td, th { padding: 5px; } tr:nth-child(even) { background-color: #dddddd; } Model Curves Phases Motorpower[kW] Energyclassi-fication Voltage[V] Current[A] Pressuremax. [mbar] Vacuummax. [mbar] SKV-NDF-500-3-937 A320 3~ 4,3 IE1 345-415 Δ / 600-720 Y 9,5 +140 -150 SKV-NDF-500-3-947 A322 3~ 5,5 IE1 345-415 Δ / 600-720 Y 13,3 +260 -240 SKV-NDF-500-3-957 A324 3~ 7,5 IE1 345-415 Δ / 600-720 Y 16,7 +320 -240 SKV-NDF-500-3-836 1 3~ 4,0 IE2 200-260 Δ / 350-450 Y 8,4 +130 -140 SKV-NDF-500-3-846 2 3~ 5,5 IE2 200-260 Δ / 350-450 Y 11,1 +220 -240 SKV-NDF-500-3-856 3 3~ 7,5 IE2 Sold out -> Replacement model: SKV-NDF-500-3-P56 SKV-NDF-500-3-P36 1 3~ 4,6 IE3 190-210 YY /220-240 Δ / 380-420 Y 8,6 +160 -180 SKV-NDF-500-3-P46 2 3~ 6,3 IE3 190-210 YY /220-240 Δ / 380-420 Y 11,8 +260 -240 SKV-NDF-500-3-P56 3 3~ 8,6 IE3 190-210 YY /220-240 Δ / 380-420 Y 15,5 +320 -240 For 3-D drawings / STEP files please send us an e-mail.
double flute ring blower with belt drive: SKV-NDF-500-BD Connection thread: G 2"Motor: not included Speed (rpm): 3000 3600 4200 5000 Air flow (m³/h): 500 600 700 800 Pressure max: (mbar) 320 300 200 80 Vacuum max: (mbar) 240 270 200 110 For 3-D drawings / STEP files please send us an e-mail.
Double stage ring blower with following specifications for 50 Hz: Max. air flow: 520 m³/hConnection thread: G 2½" table { border-collapse: collapse; width: 100%; } td, th { padding: 5px; } tr:nth-child(even) { background-color: #dddddd; } Model Curves Phases Motorpower[kW] Energyclassi-fication Voltage[V] Current[A] Pressuremax. [mbar] Vacuummax. [mbar] SKV-ND-520-3-917 A350 (1) 3~ 5,5 IE1 345-415 Δ / 600-720 Y 13,3 +260 -280 SKV-ND-520-3-927 A352 (2) 3~ 7,5 IE1 345-415 Δ / 600-720 Y 16,7 +400 -400 SKV-ND-520-3-937 A354 (3) 3~ 11,0 IE1 345-415 Δ / 600-720 Y 28,0 +600 -430 SKV-ND-520-3-947 A356 (4) 3~ 15,0 IE1 345-415 Δ / 600-720 Y 32,5 +670 -460 SKV-ND-520-3-816 1 3~ 5,5 IE2 200-260 Δ / 350-450 Y 11,1 +200 -220 SKV-ND-520-3-826 2 3~ 7,5 IE2 200-260 Δ / 350-450 Y 15,0 +350 -380 SKV-ND-520-3-836 3 3~ 11,0 IE2 200-260 Δ / 350-450 Y 22,0 +560 -430 SKV-ND-520-3-846 4 3~ 15,0 IE2 200-260 Δ / 350-450 Y 30,5 +670 -460 SKV-ND-520-3-726 1 3~ 8,6 IE3 220-240 Δ / 380-420 Y 15,5 +400 -420 SKV-ND-520-3-736 2 3~ 12,6 IE3 220-240 Δ / 380-420 Y 23,3 +650 -460 SKV-ND-520-3-P46 3 3~ 17,3 IE3 190-210 YY /220-240 Δ / 380-420 Y 31,7 +670 -460 For 3-D drawings / STEP files please send us an e-mail.
Single stage ring blower with following specifications for 50 Hz: Max. air flow: 530 m³/hConnection thread: G 2½" table { border-collapse: collapse; width: 100%; } td, th { padding: 5px; } tr:nth-child(even) { background-color: #dddddd; } Model Curves Phases Motorpower[kW] Energyclassi-fication Voltage[V] Current[A] Pressuremax. [mbar] Vacuummax. [mbar] SKV-NS-530-3-907 A340 3~ 4,0 IE1 345-415 Δ / 600-720 Y 9,5 +200 -200 SKV-NS-530-3-917 A342 3~ 5,5 IE1 345-415 Δ / 600-720 Y 13,3 +300 -300 SKV-NS-530-3-927 A344 3~ 7,5 IE1 345-415 Δ / 600-720 Y 16,7 +430 -320 SKV-NS-530-3-806 1 3~ 4,0 IE2 Sold out -> Replacement model: SKV-NS-530-3-P06 SKV-NS-530-3-816 2 3~ 5,5 IE2 200-260 Δ / 350-450 Y 11,1 +280 -300 SKV-NS-530-3-826 3 3~ 7,5 IE2 200-260 Δ / 350-450 Y 15,0 +410 -320 SKV-NS-530-3-P06 1 3~ 4,6 IE3 190-210 YY /220-240 Δ / 380-420 Y 8,6 +210 -220 SKV-NS-530-3-P16 2 3~ 6,3 IE3 190-210 YY /220-240 Δ / 380-420 Y 11,8 +320 -320 SKV-NS-530-3-726 3 3~ 8,6 IE3 220-240 Δ / 380-420 Y 15,5 +450 -320 For 3-D drawings / STEP files please send us an e-mail.
Single stage ring blower with following specifications for 50 Hz: Max. air flow: 700 m³/hConnection thread: G 2½" table { border-collapse: collapse; width: 100%; } td, th { padding: 5px; } tr:nth-child(even) { background-color: #dddddd; } Model Curves Phases Motorpower[kW] Energyclassi-fication Voltage[V] Current[A] Pressuremax. [mbar] Vacuummax. [mbar] SKV-NS-700-3-907 A360 3~ 4,0 IE1 345-415 Δ / 600-720 Y 9,5 +140 -150 SKV-NS-700-3-917 A362 3~ 5,5 IE1 345-415 Δ / 600-720 Y 13,3 +190 -200 SKV-NS-700-3-927 A364 3~ 7,5 IE1 345-415 Δ / 600-720 Y 16,7 +260 -270 SKV-NS-700-3-806 1 3~ 4,0 IE2 Sold out -> Replacement model: SKV-NS-700-3-P06 SKV-NS-700-3-816 2 3~ 5,5 IE2 200-260 Δ / 350-450 Y 11,1 +190 -200 SKV-NS-700-3-826 3 3~ 7,5 IE2 200-260 Δ / 350-450 Y 15,0 +260 -270 SKV-NS-700-3-P06 1 3~ 4,6 IE3 190-210 YY /220-240 Δ / 380-420 Y 8,6 +140 -150 SKV-NS-700-3-716 2 3~ 6,3 IE3 220-240 Δ / 380-420 Y 11,8 +230 -250 SKV-NS-700-3-726 3 3~ 8,6 IE3 220-240 Δ / 380-420 Y 15,5 +340 -290 For 3-D drawings / STEP files please send us an e-mail.