-
Ring blower
- single stage ring blower with motor
- double stage ring blower with motor
- double flute ring blower with motor
- single stage ring blower for belt drive
- double stage ring blower for belt drive
- double flute ring blower for belt drive
- single stage high pressure ring blower
- double stage high pressure ring blower
- triple stage high pressure ring blower
- mini ring blower with DC motor
- selection tool
- Rotary vane pump
- Comparative tables
- Options
- FAQ
Ring Blowers (Catalog [PDF])
| ring blower | high pressure ring blower (with motor) |
Mini ring blower (with external Controller) |
|
|---|---|---|---|
| with motor | with belt drive (no motor) |
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|

Side channel blower (also named: Regenerative blower, Ring blower, Vortex blower)
are used everywhere when it is necessary to move air or gas (with vacuum or pressure).
Side channel blowers are build in different sizes and technic depending on the air flow
or pressure / vacuum that is needed:
single stage ring blower for medium air volumes
double stage ring blower for higher pressures
double flute ring blower for higher air volumes
single stage high pressure ring blower for high pressures
double stage high pressure ring blower for higher pressures
three stage high pressure blower for very high pressures
Side channel blower - Function
while the resulting centrifugal force pushes the gas outwards into the side channel.
In this way, spiral-shaped turbulences are created. During these turbulences, the
Side Channel Blowers - Applications
Mechanical engineering
Within mechanical engineering and construction, side channel blowers are used everywhere,
where it is necessary to compress or to suction air and various gases. They are for example
frequently used in vacuum grippers to transport flat pieces.
Another frequent usage is to dry surfaces after galvanic baths or cleaning with water. Here the high speed
of air flow, typically increased by air knives, is used to forcibly remove the droplets.
Construction
Ring blowers are also used, for example remediating damage caused by water. The aim is to remove
humidity from a layer within the wall, usually the insulation layer. Dry air is pressed into the wet insulation layer or under different operating
principles, the air is being sucked out of it, the warm air slowly absorbs the humidity and removes it from the contaminated layer. A certain
pressure is needed to create an airflow within the dense insulation layer. For removing larger ammounts of water, side channel blowers are
used as well. Water can be sucked out of the insulation layer and is then removed in a separator. On the other hand, clean water can also be
pressed into the insulation layer to purge it of possible contaminents.
Other applications
Whirlpools
Pond ventilation
Biogas plants
Wood gas
Fish farms
Hoovers
Swimming pools
Vacuum tables
and much more
single stage ring blower with belt drive: SKV-NS-210-BD Connection thread: G 2"Motor: not included Speed (rpm): 3000 3600 4200 5000 Air flow (m³/h): 210 255 300 350 Pressure max: (mbar) 270 290 270 240 Vacuum max: (mbar) 220 260 300 270 For 3-D drawings / STEP files please send us an e-mail.
Triple stage high pressure ring blower with following specifications for 50 Hz: Max. air flow: 225 m³/hConnection thread: G 2" table { border-collapse: collapse; width: 100%; } td, th { padding: 5px; } tr:nth-child(even) { background-color: #dddddd; } Model Curves Phases Motorpower[kW] Energyclassi-fication Voltage[V] Current[A] Pressuremax. [mbar] Vacuummax. [mbar] SKV-HT-225-3-P36 1 3~ 4,6 IE3 190-210 YY /220-240 Δ / 380-420 Y 8,6 +430 -420 SKV-HT-225-3-746 2 3~ 6,3 IE3 220-240 Δ / 380-420 Y 11,8 +850 -650 SKV-HT-225-3-756 3 3~ 8,6 IE3 220-240 Δ / 380-420 Y 15,5 +1020 -650 For 3-D drawings / STEP files please send us an e-mail.
Double stage high pressure ring blower with following specifications for 50 Hz: Max. air flow: 225 m³/hConnection thread: G 2" table { border-collapse: collapse; width: 100%; } td, th { padding: 5px; } tr:nth-child(even) { background-color: #dddddd; } Model Curves Phases Motorpower[kW] Energyclassi-fication Voltage[V] Current[A] Pressuremax. [mbar] Vacuummax. [mbar] SKV-HD-225-3-P26 1 3~ 3,45 IE3 190-210 YY /220-240 Δ / 380-420 Y 6,7 +260 -300 SKV-HD-225-3-736 2 3~ 4,6 IE3 220-240 Δ / 380-420 Y 8,6 +420 -480 SKV-HD-225-3-746 3 3~ 6,3 IE3 220-240 Δ / 380-420 Y 11,8 +720 -530 SKV-HD-225-3-756 4 3~ 8,6 IE3 220-240 Δ / 380-420 Y 15,5 +900 -530 For 3-D drawings / STEP files please send us an e-mail.
Double stage ring blower with following specifications for 50 Hz: Max. air flow: 230 m³/hConnection thread: G 2" table { border-collapse: collapse; width: 100%; } td, th { padding: 5px; } tr:nth-child(even) { background-color: #dddddd; } Model Curves Phases Motorpower[kW] Energyclassi-fication Voltage[V] Current[A] Pressuremax. [mbar] Vacuummax. [mbar] SKV-ND-230-3-946 A240 3~ 3,0 IE1 200-240 Δ / 345-415 Y 7,2 +410 -340 SKV-ND-230-3-957 A242 3~ 4,0 IE1 345-415 Δ / 600-720 Y 9,5 +440 -390 SKV-ND-230-3-846 1 3~ 3,0 IE2 Sold out -> Replacement model: SKV-ND-230-3-746 SKV-ND-230-3-746 1 3~ 3,45 IE3 220-240 Δ / 380-420 Y 6,7 +410 -370 SKV-ND-230-3-P56 2 3~ 4,6 IE3 190-210 YY /220-240 Δ / 380-420 Y 8,9 +500 -370 For 3-D drawings / STEP files please send us an e-mail.
double stage ring blower with belt drive: SKV-ND-230-BD Connection thread: G 2"Motor: not included For 3-D drawings / STEP files please send us an e-mail. Speed (rpm): 3000 3600 4200 5000 Air flow (m³/h): 230 275 320 380 Pressure max: (mbar) 440 480 480 410 Vacuum max: (mbar) 390 410 440 460
Single stage ring blower with following specifications for 50 Hz: Max. air flow: 280 m³/hConnection thread: G 2" table { border-collapse: collapse; width: 100%; } td, th { padding: 5px; } tr:nth-child(even) { background-color: #dddddd; } Model Curves Phases Motorpower[kW] Energyclassi-fication Voltage[V] Current[A] Pressuremax. [mbar] Vacuummax. [mbar] SKV-NS-280-3-906 A270 3~ 1,6 IE1 200-240 Δ / 345-415 Y 4,9 +180 -170 SKV-NS-280-3-916 A272 3~ 2,2 IE1 200-240 Δ / 345-415 Y 5,6 +220 -235 SKV-NS-280-3-926 A274 3~ 3,0 IE1 200-240 Δ / 345-415 Y 7,2 +280 -280 SKV-NS-280-3-806 1 3~ 1,5 IE2 Sold out -> Replacement model: SKV-NS-280-3-P06 SKV-NS-280-3-816 2 3~ 2,2 IE2 200-260 Δ / 350-450 Y 4,6 +180 -190 SKV-NS-280-3-826 3 3~ 3,0 IE2 200-260 Δ / 350-450 Y 6,5 +240 -250 SKV-NS-280-3-P06 1 3~ 1,75 IE3 190-210 YY /220-240 Δ / 380-420 Y 3,45 +130 -140 SKV-NS-280-3-P16 2 3~ 2,5 IE3 190-210 YY /220-240 Δ / 380-420 Y 5,0 +200 -230 SKV-NS-280-3-P26 3 3~ 3,45 IE3 190-210 YY /220-240 Δ / 380-420 Y 6,9 +300 -280 For 3-D drawings / STEP files please send us an e-mail.
single stage ring blower with belt drive: SKV-NS-280-BD Connection thread: G 2"Motor: not included Speed (rpm): 3000 3600 4200 5000 Air flow (m³/h): 280 315 400 480 Pressure max: (mbar) 250 280 280 220 Vacuum max: (mbar) 260 280 270 220 For 3-D drawings / STEP files please send us an e-mail.
Triple stage high pressure ring blower with following specifications for 50 Hz: Max. air flow: 315 m³/hConnection thread: G 2½" table { border-collapse: collapse; width: 100%; } td, th { padding: 5px; } tr:nth-child(even) { background-color: #dddddd; } Model Curves Phases Motorpower[kW] Energyclassi-fication Voltage[V] Current[A] Pressuremax. [mbar] Vacuummax. [mbar] SKV-HT-315-3-P46 1 3~ 6,3 IE3 190-210 YY /220-240 Δ / 380-420 Y 11,8 +480 -590 SKV-HT-315-3-756 2 3~ 8,6 IE3 220-240 Δ / 380-420 Y 15,5 +750 -650 SKV-HT-315-3-766 3 3~ 12,6 IE3 220-240 Δ / 380-420 Y 23,3 +1020 -650 For 3-D drawings / STEP files please send us an e-mail.
Double stage high pressure ring blower with following specifications for 50 Hz: Max. air flow: 315 m³/hConnection thread: G 2½" table { border-collapse: collapse; width: 100%; } td, th { padding: 5px; } tr:nth-child(even) { background-color: #dddddd; } Model Curves Phases Motorpower[kW] Energyclassi-fication Voltage[V] Current[A] Pressuremax. [mbar] Vacuummax. [mbar] SKV-HD-315-3-P36 1 3~ 4,6 IE3 190-210 YY /220-240 Δ / 380-420 Y 8,6 +370 -420 SKV-HD-315-3-746 2 3~ 6,3 IE3 220-240 Δ / 380-420 Y 11,8 +550 -530 SKV-HD-315-3-756 3 3~ 8,6 IE3 220-240 Δ / 380-420 Y 15,5 +820 -530 SKV-HD-315-3-766 4 3~ 12,6 IE3 220-240 Δ / 380-420 Y 23,3 +870 -530 For 3-D drawings / STEP files please send us an e-mail.
Single stage high pressure ring blower with following specifications for 50 Hz: Max. air flow: 315 m³/hConnection thread: G 2½" table { border-collapse: collapse; width: 100%; } td, th { padding: 5px; } tr:nth-child(even) { background-color: #dddddd; } Model Curves Phases Motorpower[kW] Energyclassi-fication Voltage[V] Current[A] Pressuremax. [mbar] Vacuummax. [mbar] SKV-HS-315-3-736 1 3~ 4,6 IE3 220-240 Δ / 380-420 Y 8,6 +440 -350 SKV-HS-315-3-746 2 3~ 6,3 IE3 220-240 Δ / 380-420 Y 11,8 +500 -350 For 3-D drawings / STEP files please send us an e-mail.
Single stage ring blower with following specifications for 50 Hz: Max. air flow: 318 m³/hConnection thread: G 2" table { border-collapse: collapse; width: 100%; } td, th { padding: 5px; } tr:nth-child(even) { background-color: #dddddd; } Model Curves Phases Motorpower[kW] Energyclassi-fication Voltage[V] Current[A] Pressuremax. [mbar] Vacuummax. [mbar] SKV-NS-318-3-906 A290 3~ 1,6 IE1 200-240 Δ / 345-415 Y 4,9 +150 -160 SKV-NS-318-3-916 A292 3~ 2,2 IE1 200-240 Δ / 345-415 Y 5,6 +190 -190 SKV-NS-318-3-926 A294 3~ 3,0 IE1 200-240 Δ / 345-415 Y 7,2 +270 -260 SKV-NS-318-3-937 A296 3~ 4,0 IE1 345-415 Δ / 600-720 Y 9,5 +360 -290 SKV-NS-318-3-806 1 3~ 1,5 IE2 Sold out -> Replacement model: SKV-NS-318-3-706 SKV-NS-318-3-816 2 3~ 2,2 IE2 200-260 Δ / 350-450 Y 4,6 +170 -180 SKV-NS-318-3-826 3 3~ 3,0 IE2 200-260 Δ / 350-450 Y 6,5 +250 -260 SKV-NS-318-3-836 4 3~ 4,0 IE2 Sold out -> Replacement model: SKV-NS-318-3-736 SKV-NS-318-3-706 1 3~ 1,75 IE3 200-240 Δ / 380-420 Y 3,45 +120 -130 SKV-NS-318-3-P16 2 3~ 2,5 IE3 190-210 YY /220-240 Δ / 380-420 Y 5,0 +190 -200 SKV-NS-318-3-726 3 3~ 3,45 IE3 200-240 Δ / 380-420 Y 6,9 +270 -260 SKV-NS-318-3-736 4 3~ 4,6 IE3 200-240 Δ / 380-420 Y 8,6 +360 -290 For 3-D drawings / STEP files please send us an e-mail.
single stage ring blower with belt drive: SKV-NS-318-BD Connection thread: G 2"Motor: not included Speed (rpm): 3000 3600 4200 5000 Air flow (m³/h): 318 380 440 530 Pressure max: (mbar) 360 310 300 270 Vacuum max: (mbar) 290 320 340 300 For 3-D drawings / STEP files please send us an e-mail.