suitable for: Side channel blowers and rotary vane vacuum pumps Function: According to standard DIN EN 60204-1, motors with a rating of more than 0.5 kW must be protected against unacceptable heating. This applies to the majority of our side channel blowers. A motor protection switch ensures both overload protection and short circuit protection for the cables and lines. If an unacceptable current increase, e.g. by overloading or blocking the motor, the motor protection switch interrupts all active conductors. An overload protector as well as phase loss protection can not be provided by a motor protection switch. For this purpose, further actions must be taken. technical data: Voltage: 400 V (3~) Rated current: 1,0 - 1,6 A Options: - Motor protection switch- Motor protection switch with housing (IP 55)- Motor protection switch with housing and 3 m power supply cable (installed)
suitable for: Side channel blowers and rotary vane vacuum pumps Function: According to standard DIN EN 60204-1, motors with a rating of more than 0.5 kW must be protected against unacceptable heating. This applies to the majority of our side channel blowers. A motor protection switch ensures both overload protection and short circuit protection for the cables and lines. If an unacceptable current increase, e.g. by overloading or blocking the motor, the motor protection switch interrupts all active conductors. An overload protector as well as phase loss protection can not be provided by a motor protection switch. For this purpose, further actions must be taken. technical data: Voltage: 400 V (3~) Rated current: 4,0 - 6,3 A Options: - Motor protection switch- Motor protection switch with housing (IP 55)- Motor protection switch with housing and 3 m power supply cable (installed)
400 V power supply cable for side channel blower Description: 400 V power supply cable with 3 m or 5 m length Note: According to standard EN 60204-1 an electric motor with a rated power of more than 0.5 kW has to be protected against overheating. The use of a motor protection switch protects the motor against overload as well as a short circuit.A direct connection without motor protection switch is only possible in accordance with this standard.
suitable for: Side channel blowers and rotary vane vacuum pumps Function: According to standard DIN EN 60204-1, motors with a rating of more than 0.5 kW must be protected against unacceptable heating. This applies to the majority of our side channel blowers. A motor protection switch ensures both overload protection and short circuit protection for the cables and lines. If an unacceptable current increase, e.g. by overloading or blocking the motor, the motor protection switch interrupts all active conductors. An overload protector as well as phase loss protection can not be provided by a motor protection switch. For this purpose, further actions must be taken. technical data: Voltage: 400 V (3~) Rated current: 10,0 - 16,0 A Options: - Motor protection switch- Motor protection switch with housing (IP 55)- Motor protection switch with housing and 3 m power supply cable (installed)
Suitable for: Rotary vane vacuum pumps Function: The non-return valves prevent a return flow when the vacuum pump or the compressor is at standstill and thus the loss of the built-up vacuum / pressure. The offered nonreturn valves are suitable for vacuum, are made of brass and have a NBR seal. They can only operate properly in vertical installation.
suitable for: Side channel blowers and rotary vane vacuum pumps Function: For the assembly of the periphery (such as vacuum gauge, vacuum regulating valve, etc.) a connecting piece (T-piece or cross-piece) is required. Technical data: Options: - G ¾" (for SKV-RVP-O-20-0020)- G 1¼" (for SKV-RVP-O-05-0040 up to -0100)- G 2" (for SKV-RVP-O-05-0160 up to -0300) Connections: 1x AG for the connection of the vacuum pump (by means of a double nipple)2x IG for the connection of the periphery (1x) and the vacuum application Material: Malleable cast iron
suitable for: Side channel blowers and rotary vane vacuum pumps Function: For the assembly of the periphery (such as vacuum gauge, vacuum regulating valve, etc.) a connecting piece (T-piece or cross-piece) is required. Technical data: Options: - G ¾" (for SKV-RVP-O-20-0020)- G 1¼" (for SKV-RVP-O-05-0040 up to -0100)- G 2" (for SKV-RVP-O-05-0160 up to -0300) Connections: 1x AG for the connection of the vacuum pump (by means of a double nipple)3x IG for the connection of the periphery (2x) and the vacuum application Material: Malleable cast iron
Exhaust filters (-120) for rotary vane vacuum pumps (oil lubricated) Article no.: 90400 20 0020 90400 05 0040 90400 05 0100 90400 05 0200 -120 suitable for /required quantity:SKV-RVP-O -20-0020: 1 pcs. -05-0040: 1 pcs. -05-0063: 2 pcs.-05-0100: 2 pcs. -05-0160: 2 pcs.-05-0200: 2 pcs.-05-0250: 4 pcs.-05-0300: 4 pcs. Diameter: 50 mm 70 mm 70 mm 72 mm Length: 120 mm 208 mm 250 mm 375 mm OEM numbers:Busch OEM 05321401540532105216 05321401560532000512 05321401570532000509 05321401590532000508
Suitable for: Rotary vane vacuum pumps Function: Vacuum control valves are used to regulate the vacuum curcuit in order to create a constant operating vacuum.The valves reach the adjustable degree of vacuum by feeding ambient air (external leakage). Technical data: Thread: G ⅛" G ½" G ¾" G 1" G 1¼" max. flow rate: 4 m³/h 20 m³/h 40 m³/h 70 m³/h
In-Line-Filter for side channel blowers and rotary vane pumps with G 1¼" connection thread suitable for: Side channel blowers and rotary vane vacuum pumps in vacuum operation Function: The use of a filter for protecting the side channel blowers as well as the rotary vane vacuum pumps is obligatory. The pumps operate with very small clearance for the compression, so penetrating dirt would damage the device. In the case of the rotary vane vacuum pumps, it would additionally decrease the service-life of the equipment. technical data: air flow: 84 m³/h fits for: G ¾": SKV-RVP-O-20-0020 G 1": SKV-NS-50 / SKV-NS-70 G 1¼": SKV-NS-55 / SKV-NS-80 / SKV-NS-95SKV-HS-47 bis HS-87SKV-HD-47 bis HD-87SKV-RVP-O-05-0040 bis -0100 Attention: the in-line filters are supplied without mounting parts by default!
table { border-collapse: collapse; width: 100%; } td, th { padding: 5px; border: 3px solid white; } tr:nth-child(even) { background-color: #dddddd; } Article no.: Article-name Sort of the oil Viscosity(at 40°C) fits forSKV-RVP-O- Packagingunit 1040-VM032-5 V-M 032 mineral 32 mm²/s 20-0020-1 5 liter 1040-VM032-20 20 liter 1040-VM046-5 V-M 046 46 mm²/s 20-0020 5 liter on request 20 liter 1040-VM068-5 V-M 068 68 mm²/s 5 liter 1040-VM068-20 20 liter 1040-VM100-5 V-M 100 100 mm²/s 05-0040up to05-0300 5 liter 1040-VM100-20 20 liter 1040-VS100-5 V-S 100 synthetic 100 mm²/s 5 liter 1040-VS100-20 20 liter
The gasket kit includes the necessary O-rings, gaskets, seals and small parts. Article no.:90400 20 0020 05 0040 05 0063 05 0100 05 0160 05 0200 05 0250 05 0300 -DS suitable forSKV-RVP-O -20-0020 -05-0040 -05-0063 -05-0100 -05-0160 -05-0200 -05-0250 -05-0300 Consisting of:(Explosion-No) 050 (2x)084 (1x)086 (2x)089 (1x)096 (1x)141 (1x)185 (1x)255 (2x) 050 (2x)084 (1x)089 (1x)096 (1x)106 (1x)136 (1x)141 (1x)185 (1x)255 (2x) 050 (2x)084 (1x)089 (1x)096 (1x)106 (1x)136 (1x)141 (1x)185 (1x)255 (2x) 050 (2x)084 (1x)089 (1x)096 (1x)106 (1x)141 (1x)154 (1x)162 (1x)185 (1x)206 (1x)255 (2x) 050 (2x)084 (1x)089 (1x)096 (1x)106 (1x)141 (1x)154 (1x)162 (1x)185 (1x)206 (1x)255 (2x) similar to:(Busch OEM) 0990121239 0990101464 0990106211 0990516589 0993506360