suitable for: Side channel blowers and rotary vane vacuum pumps Function: In order to install peripherals (e.g. in-line filters, t-necks). (check the dimensions of the model) Technical data: Material: - PVC
suitable for: Side channel blowers and rotary vane vacuum pumps Function: In order to install certain peripherals (e.g. vacuum manometers, vacuum control valves) a suitable adapter and, if necessary, a connection piece (T-neck or cross fitting) is needed. Technical data: common connections: Pressure-manometer to monitor exhaust filters:- AG ¾" to IG ¼" (for manometers with G ¼")- AG ¾" to IG ½" (for manometers with G ½")Vacuum-manometer on T-neck or cross-piece:- G ¾" to G ¼" / ½" (for SKV-RVP-O-20-0020)- G 1¼" to G ¼" / ½" (for SKV-RVP-O-05-0040 to -0100)- G 2" to G ¼" / ½" (for SKV-RVP-O-05-0160 to -0300)Vacuum control valve at T-neck or cross-piece:- G 1¼" to G 1" / ¾" (for SKV-RVP-O-05-0040 to -0063) Material: - Brass- malleable cast iron, galvanized- PVC-U (only suitable for rotary vane pumps under certain conditions)
suitable for: Side channel blowers and rotary vane vacuum pumps Function: In order to install certain peripherals (e.g. in-line filters, t-necks) a suitable pipe nipple is needed. (check the dimensions of the model) Technical data: Material: - malleable cast iron, galvanized
Oil filter (-100) for rotary vane vacuum pumps (oil lubricated) Article no.: 90400 05 0100 90400 05 0200 -100 suitable for SKV-RVP-O-05-0040SKV-RVP-O-05-0063SKV-RVP-O-05-0100 SKV-RVP-O-05-0160SKV-RVP-O-05-0200SKV-RVP-O-05-0250SKV-RVP-O-05-0300 OEM number:Busch OEM 0531000002 0531000001
Function: Tube adapter for side channel blowers and rotary vane vacuum pumps with connection thread G ½" - 2" technical data: Thread: G ½" G ¾" G 1" G 1¼" G 1¼" G 1½" G 2" Diameter: 16 mm 20 mm 25 mm 32 mm 38 mm 38 mm 50 mm Material: brass
Paper spare filter for In-Line FilterPlease choose your size: G 1¼" G 1½" G 2" G 2½" G 3" G 4"
PUR - tube with diameter 32 mm - 115 mm suitable for: Side channel blowers in vacuum and pressure operation Function: PUR tubes with spiral reinforcement are suitable for many applications, as they are resistant to pressure as well as vacuum.This PUR tube can be used as transport hose for polymer pellets. technical data: Design: high quality PUR-tube with metal reinforcement Properties: inside smooth, outside corrugatedflexiblehardly inflammable (DIN 4102 B1)temperature: -40°C up to +90°Cantistatic < 10⁹ Ohmhighly abrasion resistancecolor: translucent Tube dimensions: DN: 32 / 38 / 40 / 45 / 50 / 60 / 80 / 100 / 115 mm
230 V power supply cable for side channel blower Description: 230 V power supply cable with 3 m or 5 m length
suitable for: Side channel blowers and rotary vane vacuum pumps Function: In order to easily install certain peripherals (e.g. in-line filters, t-necks) a suitable 90° bend is needed. (check the dimensions of the model) Description: Contains a 90° bend (normed, long version) with one inner and one outer thread, as well as a double nipple (2x outer thread) Technical data: Material: bend: malleable cast iron, galvanized / double nipple: PVC-U
suitable for: Side channel blowers and rotary vane vacuum pumps Function: According to standard DIN EN 60204-1, motors with a rating of more than 0.5 kW must be protected against unacceptable heating. This applies to the majority of our side channel blowers. A motor protection switch ensures both overload protection and short circuit protection for the cables and lines. If an unacceptable current increase, e.g. by overloading or blocking the motor, the motor protection switch interrupts all active conductors. An overload protector as well as phase loss protection can not be provided by a motor protection switch. For this purpose, further actions must be taken. technical data: Voltage: 400 V (3~) Rated current: 2,5 - 4,0 A Options: - Motor protection switch- Motor protection switch with housing (IP 55)- Motor protection switch with housing and 3 m power supply cable (installed)
suitable for: Side channel blowers and rotary vane vacuum pumps Function: According to standard DIN EN 60204-1, motors with a rating of more than 0.5 kW must be protected against unacceptable heating. This applies to the majority of our side channel blowers. A motor protection switch ensures both overload protection and short circuit protection for the cables and lines. If an unacceptable current increase, e.g. by overloading or blocking the motor, the motor protection switch interrupts all active conductors. An overload protector as well as phase loss protection can not be provided by a motor protection switch. For this purpose, further actions must be taken. technical data: Voltage: 400 V (3~) Rated current: 1,6 - 2,5 A Options: - Motor protection switch- Motor protection switch with housing (IP 55)- Motor protection switch with housing and 3 m power supply cable (installed)
suitable for: Side channel blowers and rotary vane vacuum pumps Function: According to standard DIN EN 60204-1, motors with a rating of more than 0.5 kW must be protected against unacceptable heating. This applies to the majority of our side channel blowers. A motor protection switch ensures both overload protection and short circuit protection for the cables and lines. If an unacceptable current increase, e.g. by overloading or blocking the motor, the motor protection switch interrupts all active conductors. An overload protector as well as phase loss protection can not be provided by a motor protection switch. For this purpose, further actions must be taken. technical data: Voltage: 400 V (3~) Rated current: 6,3 - 10,0 A Options: - Motor protection switch- Motor protection switch with housing (IP 55)- Motor protection switch with housing and 3 m power supply cable (installed)