Ring blower
- single stage ring blower with motor
- double stage ring blower with motor
- double flute ring blower with motor
- single stage ring blower for belt drive
- double stage ring blower for belt drive
- double flute ring blower for belt drive
- single stage high pressure ring blower
- double stage high pressure ring blower
- triple stage high pressure ring blower
- mini ring blower with DC motor
- selection tool
- Rotary vane pump
- Comparative tables
- Options
- FAQ
double flute ring blower with motor
from 500 - 3200 m³/h
comparison tables for models from other manufacturers
Are IE2 motors the better choice?
(advantages and cost analysis)
Double flute ring blower with following specifications for 50 Hz: Max. air flow: 500 m³/hConnection thread: G 2" table { border-collapse: collapse; width: 100%; } td, th { padding: 5px; } tr:nth-child(even) { background-color: #dddddd; } Model Curves Phases Motorpower[kW] Energyclassi-fication Voltage[V] Current[A] Pressuremax. [mbar] Vacuummax. [mbar] SKV-NDF-500-3-937 A320 3~ 4,3 IE1 345-415 Δ / 600-720 Y 9,5 +140 -150 SKV-NDF-500-3-947 A322 3~ 5,5 IE1 345-415 Δ / 600-720 Y 13,3 +260 -240 SKV-NDF-500-3-957 A324 3~ 7,5 IE1 345-415 Δ / 600-720 Y 16,7 +320 -240 SKV-NDF-500-3-836 1 3~ 4,0 IE2 200-260 Δ / 350-450 Y 8,4 +130 -140 SKV-NDF-500-3-846 2 3~ 5,5 IE2 200-260 Δ / 350-450 Y 11,1 +220 -240 SKV-NDF-500-3-856 3 3~ 7,5 IE2 Sold out -> Replacement model: SKV-NDF-500-3-P56 SKV-NDF-500-3-P36 1 3~ 4,6 IE3 190-210 YY /220-240 Δ / 380-420 Y 8,6 +160 -180 SKV-NDF-500-3-P46 2 3~ 6,3 IE3 190-210 YY /220-240 Δ / 380-420 Y 11,8 +260 -240 SKV-NDF-500-3-P56 3 3~ 8,6 IE3 190-210 YY /220-240 Δ / 380-420 Y 15,5 +320 -240 For 3-D drawings / STEP files please send us an e-mail.
Double flute ring blower with following specifications for 50 Hz: Max. air flow: 900 m³/hConnection thread: G 2½" table { border-collapse: collapse; width: 100%; } td, th { padding: 5px; } tr:nth-child(even) { background-color: #dddddd; } Model Curves Phases Motorpower[kW] Energyclassi-fication Voltage[V] Current[A] Pressuremax. [mbar] Vacuummax. [mbar] SKV-NDF-900-3-927 A370 3~ 7,5 IE1 345-415 Δ / 600-720 Y 16,7 +180 -200 SKV-NDF-900-3-937 A372 3~ 11,0 IE1 345-415 Δ / 600-720 Y 28,0 +370 -280 SKV-NDF-900-3-826 1 3~ 7,5 IE2 200-260 Δ / 350-450 Y 15,0 +180 -190 SKV-NDF-900-3-836 2 3~ 11,0 IE2 200-260 Δ / 350-450 Y 22,0 +320 -280 SKV-NDF-900-3-P26 1 3~ 8,6 IE3 190-210 YY /220-240 Δ / 380-420 Y 15,5 +180 -200 SKV-NDF-900-3-P36 2 3~ 12,6 IE3 190-210 YY /220-240 Δ / 380-420 Y 23,3 +330 -320 SKV-NDF-900-3-P46 3 3~ 17,3 IE3 190-210 YY /220-240 Δ / 380-420 Y 31,7 +420 -320 For 3-D drawings / STEP files please send us an e-mail.
Double flute ring blower with following specifications for 50 Hz: Max. air flow: 1940 m³/hConnection thread: G 4" table { border-collapse: collapse; width: 100%; } td, th { padding: 5px; } tr:nth-child(even) { background-color: #dddddd; } Model Curves Phases Motorpower[kW] Energyclassi-fication Voltage[V] Current[A] Pressuremax. [mbar] Vacuummax. [mbar] SKV-NDF-1940-3-927 A410 3~ 15,0 IE1 345-415 Δ / 600-720 Y 35,0 +110 -130 SKV-NDF-1940-3-937 A412 3~ 20,0 IE1 345-415 Δ / 600-720 Y 40,0 +200 -220 SKV-NDF-1940-3-946 A414 3~ 25,0 IE1 200-240 Δ / 345-415 Y 52,0 +270 -310 SKV-NDF-1940-3-947 A414 3~ 25,0 IE1 345-415 Δ / 600-720 Y 52,0 +270 -310 SKV-NDF-1940-3-826 1 3~ 15,0 IE2 Sold out -> Replacement model: SKV-NDF-1940-3-726 SKV-NDF-1940-3-836 2 3~ 18,5 IE2 Sold out -> Replacement model: SKV-NDF-1940-3-P36 SKV-NDF-1940-3-726 1 3~ 17,3 IE3 220-240 Δ / 380-420 Y 31,7 +140 -150 SKV-NDF-1940-3-P36 2 3~ 21,3 IE3 190-210 YY /220-240 Δ / 380-420 Y 38,3 +200 -220 SKV-NDF-1940-3-P46 3 3~ 25,3 IE3 190-210 YY /220-240 Δ / 380-420 Y 46,5 +300 -300 For 3-D drawings / STEP files please send us an e-mail.
Double flute ring blower with following specifications for 50 Hz: Max. air flow: 2050 m³/hConnection: 201 mm flange table { border-collapse: collapse; width: 100%; } td, th { padding: 5px; } tr:nth-child(even) { background-color: #dddddd; } Model Curves Phases Motorpower[kW] Energyclassi-fication Voltage[V] Current[A] Pressuremax. [mbar] Vacuummax. [mbar] SKV-NDF-2050-3-927 A420 3~ 15,0 IE1 345-415 Δ / 600-720 Y 35,0 +170 -160 SKV-NDF-2050-3-937 A422 3~ 20,0 IE1 345-415 Δ / 600-720 Y 40,0 +230 -250 SKV-NDF-2050-3-947 A424 3~ 25,0 IE1 345-415 Δ / 600-720 Y 52,0 +270 -310 SKV-NDF-2050-3-826 1 3~ 15,0 IE2 Sold out -> Replacement model: SKV-NDF-2050-3-726 SKV-NDF-2050-3-836 2 3~ 18,5 IE2 200-260 Δ / 350-450 Y 32,0 +200 -220 SKV-NDF-2050-3-726 1 3~ 17,3 IE3 220-240 Δ / 380-420 Y 31,7 +170 -160 SKV-NDF-2050-3-P36 2 3~ 21,3 IE3 190-210 YY /220-240 Δ / 380-420 Y 38,3 +230 -250 SKV-NDF-2050-3-P46 3 3~ 25,3 IE3 190-210 YY /220-240 Δ / 380-420 Y 46,5 +280 -310 For 3-D drawings / STEP files please send us an e-mail.
Triple flute ring blower with following specifications for 50 Hz: Max. air flow: 3200 m³/hConnection: 201 mm flange table { border-collapse: collapse; width: 100%; } td, th { padding: 5px; } tr:nth-child(even) { background-color: #dddddd; } Model Curves Phases Motorpower[kW] Energyclassi-fication Voltage[V] Current[A] Pressuremax. [mbar] Vacuummax. [mbar] SKV-NTF-3200-3-716 1 3~ 25,3 IE3 220-240 Δ / 380-420 Y 46,5 +220 -290 For 3-D drawings / STEP files please send us an e-mail.